7. Diagnosis
7.11 MELDASNET Support Parameters
I
-311
7.11 MELDASNET Support Parameters
Pressing the menu key
SUPPORT
displays the MELDASNET SUPPORT PARAMETER screen.
AUX-PRM AUX-MON SUPPORT MENU
[SUPPORT] ALARM/DIAGN 11.1/2
<STATE> <SAMPLING DATA SELECT>
Sampling #11 H/W CONFIG 0 #23 COORDINATE DATA 0
#12 S/W CONFIG 0
<OPE> #13 KEY HISTORY 0
#1 Sampling #14 ALARM HISTORY 0
0: Start #15 PLC I/O HISTORY 0
#2 Sampl. data clear #16 AC ALARM HISTORY 0
1: Clear #17 SPINDLE DATA1 0
<SAMPLING SPEC> #18 SPINDLE DATA2 0
#5 System 0 #19 SERVO DATA1 0
#6 Spindle 0 #20 SERVO DATA2 0
#7 Servo 0000 #21 MODAL 0
#22 PROGRAM DATA 0
#( )( )
After setting #5 to #7 and #11 to #23, turn the NC power OFF. The settings will be validated after the power
is turned ON again.